Specification Sheet
Performance you rely on.
TM
  cumminsonan.com 
©2015 Cummins Power Generation Inc. | A-1425m (8/15) 
Specification sheet 
RV generator set
Quiet Gasoline
TM
Series RV QG 
5500 
Features and benefits 
 Quietest in its class. 
 Exceptionally low vibration levels. 
 Integrated design with enclosed muffler for 
easy installation. 
 Self-diagnostic capability to simplify 
troubleshooting. 
 Runs one or two air conditioners with power 
to spare. 
 Digital voltage regulation for stability as 
appliance loads change. 
 3-year limited warranty, lifetime drive 
warranty. 
 Gasoline or LP fueled. 
Weight, size and sound level 
Weight: 
288 lbs (131 kg) 
Size: 
Length 33.6 in (853 mm), width 22.2 in 
(563 mm), height 16.7 in (425 mm) 
Sound:
 69
 dB(A) readings at 10 ft (3 m) half load 
  Meets National Park Service sound level requirements 
(60 dB(A) @ 50 ft) for use in national parks. 
 Typical installation will further reduce sound level. 
Models and ratings 
Model Fuel Packaging Hz RPM Watts Voltage Amps Phase 
Circuit 
breaker 
5.5 HGJAB-1270 (1381**) 
LP vapor  Tubbed  60  2400  5500  120  45.8  1  (2) 30 A 
5.5 HGJAB-1119 (1220**) 
LP vapor  Tubbed
  60 2400  5500  120  45.8  1 
(1) 30 A, (1) 
20 A HACR 
5.5 HGJAB-1038 (1049**) 
Gasoline Tubbed 60 2400  5500  120  45.8  1  (2) 30 A 
5.5 HGJAB-901 (912**) 
Gasoline Tubbed
  60 2400  5500  120  45.8  1 
(1) 30 A, (1) 
20 A HACR 
5.5 HGJAB-6755* (7866**) 
Gasoline Tubbed
  60 2400  5500  120  45.8  1 
(2) 30 A, (1) 
20 A HACR 
5.5 HGJAB-7103* (8214**) 
Gasoline Tubbed
  60 2400  5500  120  45.8  1 
(2) 30 A, (1) 
20 A HACR 
Ambient conditions for rated power output with muffler and RV enclosure, per ISO 8528-1: 
- Temperature: 77° F (25° C) 
- Altitude: 500 ft (152.4 m), (99 kPa dry) 
Typical power output change based on ambient conditions: 
- Temperature: Power output decreases 1% for every 10° F (5.5° C) increase 
- Altitude: Power output decreases 3.5% for every 1000 ft (305 m) increase 
Ratings represent minimums. Actual performance may be significantly higher based on installation and operating 
conditions. 
* Evaporative spec: Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non- 
 motorized mobile apparatus must have an EVAP generator set, approved tank, EVAP canister, hoses and fittings all 
 meeting the CARB Tier 3 and EPA phase 3 standards and specifications. This law applies in all 50 states. 
** Factory OEM packaging 
Operating temperature range
 Low High 
Gasoline 
-20° F (-29° C)  120° F (49° C) 
LP 
0° F (-18° C)  120° F (49° C) 
- Depends upon LP tank capacity, surface area and butane content of LPG. 