Specification Sheet
Performance you rely on.
TM
cumminsonan.com
©2015 Cummins Power Generation Inc. | A-1399p (8/15)
Standard features
Microprocessor control with digital voltage regulator
Starter overcrank protection
Generator set field overload protection
Over/under frequency and voltage protection
Loss of AC sense protection
Mechanical fault protection
Detects starter faults
Reverse connections and high battery voltage
protection
4-point vibration isolator mounting system
Magnetic circuit breaker
Automatic resetting of DC circuit overcurrent protection
for set wiring and remote start wiring
Integral enclosure cover and stamped steel base
Stationary exhaust pipe attachment point
High stability mechanical governor
Sealed remote start connector
Fuel filter
USDA Forest Service-approved, spark-arresting muffler
Cross-flow pressure cooling
Automatic choke
Electric fuel pump with positive fuel safety shutoff
(gasoline)
Electric fuel shutoff solenoid (LPG)
125 in (3.2 m) generator set output leads
Intake silencer, sound deadening material and baffles
reduce sound level
Start-stop/prime rocker switch on control with LED
status indicator light for set diagnostics
Engine details
Model:
Cummins Onan E095H
Design:
4-cycle, OHV, single horizontal cylinder
Displacement:
18.5 in
3
(304 cm
3
)
Compression ratio:
8.5:1
Maximum power at 60 Hz:
LPG - 8.6 bhp (6.4 kW); Gasoline: - 9.5 bhp (7 kW)
Maximum power at 50 Hz:
LPG - 7.6 bhp (5.7 kW); Gasoline - 8.3 bhp (6.2 kW)
Cooling:
Cross flow air - pressure type
Cooling air volume:
Includes engine cooling air volume
60 Hz:
300 ft
3
/min (8.5 m
3
/min)
50 Hz:
250 ft
3
/min (7.1 m
3
/min)
Combustion air volume:
60 Hz:
19 ft
3
/min (0.5 m
3
/min)
50 Hz:
16 ft
3
/min (0.45 m
3
/min)
Side draft carburetor:
KY (gasoline)
Electric fuel pump:
Positive fuel shutoff (3 psi), fuel lift
3 ft (914 mm)
Air cleaner:
Replaceable dry element; patented
automatic choke
Vapor withdrawal system with demand regulator:
KY (LPG)
Ignition system:
Electronic magneto type
Starting system:
Remote, 12 V, 3-wire negative ground
Starter:
Automotive type with environmentally protected
pinion; automatic start disconnect
Lubrication:
Splash lubrication
Oil capacity:
1.6 qt (1.5 L)
Cylinder crankcase:
Aluminum alloy with iron cylinder
liner cast into the block, aluminum alloy oil base
Cylinder head:
Aluminum, valves in head, removable
Average fuel consumption
Gasoline No load Half load Full load
60 Hz 4.0 KY
0.3 Gal/h (1.1 L/h) 0.5 Gal/h (1.8 L/h) 0.7 Gal/h (2.7 L/h)
50 Hz 3.6 KY
0.2 Gal/h (0.8 L/h) 0.4 Gal/h (1.4 L/h) 0.6 Gal/h (2.2 L/h)
LPG No load Half load Full load
60 Hz 3.6 KY
0.4 Gal/h (1.5 lb/h) 0.7 kg/h 0.6 Gal/h (2.4 lb/h) 1.1 kg/h 0.7 Gal/h (3.1 lb/h) 1.4 kg/h
50 Hz 3.3 KY
0.3 Gal/h (1.1 lb/h) 0.5 kg/h 0.5 Gal/h (2.2 lb/h) 1.0 kg/h 0.7 Gal/h (2.9 lb/h) 1.3 kg/h
Alternator details
Design:
Cummins Onan revolving field, AC, 2-pole self-
excited; permanently aligned to engine by a tapered
shaft; drip-proof construction
Insulation system and temperature rise:
Meets
ANSI/RVIA-EGS-1-1998 and CSA TIL RV-06
requirements.
Cooling:
Direct drive centrifugal blower, cast aluminum
housing for excellent heat transfer
Voltage regulation:
Microprocessor control with
digital voltage regulator
Rotor:
Laminated electrical steel assembly press fitted
to shaft, balanced; heavy insulated copper wire
windings; amortisseur windings for improved waveform
Stator:
Laminated electrical steel assembly; heavy
insulated copper wire windings
DC brushes:
Electrographite; long life
Bearing:
Double-sealed, pre-lubricated ball bearing
Generator set performance
Air conditioner starting:
(60 Hz - gasoline) one 13500
Btu air conditioner with 2000 W base load at 500 ft
(152.4 m) and 100° F (38° C)
Frequency and voltage regulation:
Exceeds
requirements of ANSI/RVIA EGS-1