Specifications

• 250,000 BTU pilot light model features
manual modulating valve (150,000 –
250,000 BTU’s).
• Hot surface & direct spark models
available in 40,000 to 250,000 BTU.
• High temp aluminized steel burn
chamber.
• Side swing door for easy access and
maintenance.
• Diagnostic lights for troubleshooting
ease.
• Standard adjustable “Y” heat deector.
• 1/3 HP totally enclosed thermally
protected motor with sealed bearings.
The “SERVICESAVER” enclosed
electrical control unit is sealed from
debris such as dust and moisture
and is accessible through a side
swinging door making the unit
easily field serviceable.
A side swinging door design gives
EASY ACCESS to internal compo-
nents like the “Super-Saver control
unit and blower motor, making it
one of the easiest to service heaters
on the market.
The ELECTRONIC HSI IGNITION
is standard on all models. The
heating chamber is made of high
temp aluminized steel for superior
rust protection. The cast iron burner
is enamel dipped to eliminate dust
adhesion and rust. The air intake
surround increases combustion and
heat change eciency.
The outside mount model is a
forced air heater complete with all
relevant installation hardware.
The inside mount model
is a gas circulating heater
ideal for a connement
environment.
• Available in 120 & 240 volt models.
• 1/10 HP on all 40,000 – 75,000 BTU
models.
• Standard ½” gas cock installed at gas
valve.
• Back-up safety sail switch.
• High limit safety switch (manual reset).
• On/O toggle switch.
• Stainless steel, high altitude & CE
certied models* available.
• Service-Saver enclosed control box.
Super-Saver XL Features & Benets
Super-Saver pilot heaters available.
Super-Saver XL Minimum Clearances
Ceiling 12” (305mm)
Wall 12” (305 mm)
Floor 20” (508 mm)
Heater must be positioned such that livestock and combustible materials are unable to
come in contact with the heater or within 10 feet (3 meters) of the hot air discharge.
LP/Propane Gas
Maximum 14 in. W.C. (34.8 mbar) and minimum 12.5 in. W.C. (31.1 mbar) inlet gas supply pressure acceptable at gas regulator connection. Burner manifold
pressure of 11 in. W.C. (27.4 mbar) at maximum input. Gas pressure should be checked by a certied gas technician while heater is in operation.
Natural Gas
Maximum 14 in. W.C. (34.8 mbar) and minimum 5 in. W.C. (12.5 mbar) inlet gas supply pressure acceptable at gas regulator connection. Burner manifold
pressure of 3.5 in. W.C. (8.7 mbar) at maximum input. Gas pressure should be checked by a certied gas technician while heater is in operation.

Model# Maximum Input Ventilation Voltage Amps
SS-40-XL 40,000 BTUH (11.7kWh) 500 CFM (849.5 m³/hr) 120 Volts 2.5 Amps
SS-75-XL 75,000 BTUH (21.9kWh) 500 CFM (849.5 m³/hr) 120 Volts 2.5 Amps
HH-SS-120-XL 120,000 BTUH (35.2kWh) 1000 CFM (1699 m³/hr) 120 Volts 4.8 Amps
HH-SS-175-XL 175,000 BTUH (36.6kWh) 1000 CFM (1699 m³/hr) 120 Volts 4.8 Amps
HH-SS-200-XL 200,000 BTUH (58.6kWh) 1000 CFM (1699 m³/hr) 120 Volts 4.8 Amps
HH-SS-225-XL* 225,000 BTUH (65.9kWh) 1000 CFM (1699 m³/hr) 120 Volts 4.8 Amps
HH-SS-250-XL 250,000 BTUH (73.3kWh) 1200 CFM (2039 m³/hr) 120 Volts 6.0 Amps
*CE certied available in the HH-SS-225-XL Model
13