User manual
6. Wiring
14 PNEG-876 APP Series Fans
Figure 6E
Propeller speeds for APP Fans stated in the table are the maximum permissible speeds. Exceeding these
may result in damage to the fan and serious injury to the operator. CFM ratings listed below were all taken
at 0.05 static pressure. Performer series fans use TEAO (Totally Enclosed Air Over) motors.
Performer series fans use TEAO (Totally Enclosed Air Over) motors that require the air movement created
by the fan to cool the motor as it passes over the motor housing. Be aware that operating variable speed
fans at too low of speed can cause the motor to overheat and result in the tripping of the automatic thermal
overload or unwarranted motor failure. There are a number of variables that affect the safe minimum
speed of a ventilation fan including ventilation control curve selection, input voltage, static pressure and
susceptibility to head winds. The correct minimum speed must be selected on a case by case basis to
ensure adequate airflow for motor cooling.
APP-12F* Speed Curve #9
Volts RPM CFM without Cone CFM with Cone
230 1765 1432 N/A
135 1675 1351 N/A
119 1575 1251 N/A
115 1475 1133 N/A
112 1375 983 N/A
111 1275 964 N/A
109 1175 780 N/A
107 1075 700 N/A
105 975 590 N/A
104 875 520 N/A
103 775 445 N/A
102 675 380 N/A
101 575 310 N/A
99 475 242 N/A
* Add - BLK suffix to end of fan model for black fans.