Specifications
27 Culligan Medallist Series
®
Water Filters
Problem Cause Solution
6. Loss of mineral to drain. A. Improper drain line ow control. A. Ensure that the control has the proper
drain line ow control. (See Table 10)
B. Air in water system. B. Ensure that system has proper air
eliminator control.
7. Mineral to service. A. Control connected to tank backwards. A. Verify that control is properly mounted to
the tank.
B. Defective outlet manifold. B. Replace outlet manifold.
8. Continuous ow to
drain.
A. Internal seal pack leak. A. Replace seal pack as outlined in the
‘Parts Replacement Guide’ section.
B. Seal pack or brine piston jammed in
position.
B. Replace the seal pack or brine piston as
outlined in the ‘Parts Replacement Guide’
section.
C. Power failure while unit was in regeneration. C. Restore power to unit. Verify that unit is
connected to a constant power source.