Specifications

25 Culligan Medallist Series
®
Water Filters
Cullar
®
and Cullneu
®
Water Filters
Connect the transformer to a grounded, 120 Volt, 60 Hertz outlet.
Initiate an extra recharge by pressing and holding the “REGEN” button for approximately 5 seconds.
SLOWLY place the bypass valve(s) in the service position.
Place the lter in bypass as soon as water is observed owing to drain, place the timer in the service position (refer to the
SERVICE POSITION paragraphs in the SETTINGS section) and unplug the control.
Allow the media to soak for 24 to 48 hours for Cullar and Cullneu models.
Plug in the power cord, and set the timer to the correct time of recharge and time of day, place the bypass valve(s) in the
service position.
Filtr-Cleer
®
Water Filter
Connect the transformer to a grounded, 120 Volt, 60 Hertz outlet.
Set the timer to the correct time of recharge and time of day.
Initiate an extra recharge by pressing and holding the “REGEN” button for approximately 5 seconds.
SLOWLY place the bypass valve(s) in the service position.
During the recharge cycle, unltered water will be available to all the lines in the household. Immediately following recharge, the
water to service will be ltered.
Recommended Preventative Maintenance Inspection Schedule
The Culligan Gold Series water filter has been designed to provide a good, consistent service life. Routinely inspecting the system
may help avoid potentially costly breakdowns related to circumstances outside of the control of the dealer and/or user. The filter is
for prblem water use and routine maintenance is required. Contact your local Culligan dealer to perform routine maintenance.
Component Suggested Inspection
Frequency
Reason for Maintenance
Entire
System
At Start-up, after infrequent
use (idle for one week or more)
or every 3 - 6 months if on a
private water supply.
On private supplies, the appearance of off-tastes and odors, particularly if musty
or “rotten egg” (caused by harmless sulfate-reducing bacteria) may indicate a
need for the system to be sanitized.
Backwash
Flow
Controller
Every 12 months or every time
service is performed on the
system.
Build up of sediment, iron and/or other foreign materials (found in some water
supplies but not necessarily all) could negatively affect system performance. Monitor
item for normal or unexpected wear.
Media As needed. Cullneu Filter - As water passes through the Cullneu filter, the media slowly
dissolves and neutralizes the water. The rate at which the Cullneu media dissolves
depends on a number of factors such as temperature flow rate and pH. Add media
when pH elevation no longer occurs.
Cullar - Replace when taste odor or chlorine can no longer be removed.
Filtr-Cleer - Media may need to be reconditioned or replaced depending on
water characteristics.
Caution! If a sudden rush of water enters the lter, some of the media could be thrown up into the control valve.
Warning! Although not normally necessary, should you need to disassemble any part of the control valve or
remove the control from the tank assembly or associated plumbing, depressurize the unit first closing the
main supply valve, then open a convenient faucet down stream from the water conditioner
Start-up Procedure
Caution! If a sudden rush of water enters the lter, some of the media could be thrown up into the control valve.