Specifications
Programming 18
The timer uses four buttons:
Button Description
Set-up / Enter Key (Status) Advance timer through display options
Regeneration Key (REGEN) Initiate a regeneration
Toggle Down Key (“-”) Decrease the setting
Toggle Up Key (“+”) Increase the setting
Time of Day
This setting is used to program the current time of day. When in this step
the display will rst show “tod” for two seconds.
After “tod” is displayed, “12:00 PM” will display (or the current set time if
already programmed) and the minutes will ash.
• The minutes are adjusted with the “+” or “- ”
key until the correct value is displayed.
• Press the “Regen” key to ash the hours. Adjust with the “+” or “- ”
key until the correct time is displayed.
Pressing the “Status” key will move to the next programming step.
Pressing “Regen” will move back to the minutes adjust.
Time of Regeneration
This setting is used to program the time at which a regeneration is to occur
in the delay mode, or in immediate mode with time clock backup on. The
display will rst show “tor” for two seconds.
After “tor” is shown the display will then show the default of 2:00 AM (or
the current programmed time of regeneration if already set). The time can
be adjusted in 30 minute increments by pressing the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next
programming step.
Backwash Time
This setting is used to program the cycle 1 time that is usually backwash.
The time of the cycle is kept in minutes. The display will show “buu” in the
display for two seconds and then the cycle time in the right most digits.
Adjust the value with the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next
programming step.