Specifications

The programming menu for Medallist is outlined in the following table:
Setting Display Range Limits Default Comments
Time of Day 12:00 AM - 11:59 PM (12hr)
00:00 - 23:59 (24hr)
12:00 PM
12:00
12 / 24 hour function set
with dip #6
*Time of Regeneration 12:00 AM - 11:30 PM (12hr)
00:00 - 23:30 (24hr)
2:00 AM
02:00
- Adjust time in 30
minute increments only
*Cycle 1 time 01 - 99 minutes 10 minutes -Always active in Time
Clock Mode
*Cycle 2 time 01 - 99 minutes - Filter: 02 minutes -Always active in Time
Clock Mode
*Cycle 3 time 01 - 99 minutes 10 minutes -Always active in Time
Clock Mode (Filter)
*Regeneration Interval Days - 01 to 99 days 03 days
Hidden Programming Menu
(Accessed from service mode by holding the “+” key for 5 seconds)
*Delay / Immediate
Toggle Delay or
Immediate
Delay - Locks in a regen
signal after a 3 hour or
more power outage;
regen can be set to go
immediate or delay until
the tor;
- Only accessible from
service mode, time of
day display, by pressing
and holding “+” for 5
seconds
- (not in programming
menu)
*Lock / Unlock Toggle Lock & Unlock Unlock - Lock or unlock access
to make program
changes
- Only accessible from
service mode, time of
day display, by pressing
and holding “+” for 5
seconds
- (not in programming
menu)
• To be saved in EEPROM
Make sure either inlet water supply is turned off, then supply power to the timer. The display will power up ashing “12:00 PM” and
the motor will energize and cycle the control, without stopping, to the home position. This is required to ensure that the control is in
the home position.
17 Culligan Medallist Series
®