Specifications

Installation 10
Mount The Control Valve - 1” Control
See Figure 6 for a visual on mounting the control valve to the tank.
Assemble the o-rings, located in the parts pack, to the tank adapter.
The valve adapter o-ring sits on the rst step on the adapter. See
Figure 7.
Lubricate only the top o-ring on the tank adapter, and the outlet
manifold o-ring with silicone lubricant.
Screw the adapter into the tank until the adapter bottoms out on the
tank ange.
Align the manifold with the center opening in the valve, and press
the valve onto the adapter rmly.
Assemble the tank clamp to the control, and tighten the clamp
screw.
Install the Flow Control
As shipped from the factory, each control is equipped with a 2 gpm ow control for 8” Cullar
®
lters. Additional ow controls are
included with each unit for conversion for use with other lter tanks. Refer to Table 1 to select the proper ow control.
Table 1
Filter Flow Control Color
8” Cullar 2.0 gpm Brown
10” Cullar 6.0 gpm Black
8” Cullneu
®
3.5 gpm Green
10” Cullneu 6.0 gpm Black
8” Filtr-Cleer
®
4.5 gpm Red
10” Filtr-Cleer 7.0 gpm* Black (Thin)
* Use with ow control spacer provided
Figure 7
Figure 6
Note: Do not push the top o-ring down to the ange surface on
the adapter.
Note: The larger of the two o-rings in the parts part goes
between the adapter and the valve, do not stretch the smaller
o-ring onto the top of the tank adapter.
Note: The adapter only needs to be tightened hand-tight to the
tank ange.
Note: Make sure to push the valve straight down onto the
manifold. If the valve is cocked, it may cause the o-ring to slip off
the manifold.
Note: The clamp and valve will be able to rotate on the tank
until pressure is applied. Do not try to rotate control valve if the