Specifications

Cullneu
®
Filters
Cullneu lters are shipped with 2 bags of Cullneu with 8” lters and 3 bags of Cullneu with 10” lters. Verify that the proper amount
of media is on site before loading.
Place the manifold inside the tank. Position the tip of the manifold in the recess located in the bottom of the tank.
Cover the top of the manifold with a clean rag.
Place a wide mouth funnel in the tank opening. The Cullneu media should be added with no water in the tank.
For 8” Cullneu lters, slowly pour the entire contents of one bag of media and enough media from the second bag to raise the
level of media in the tank to within 11” of the top of the tank.
For 10” Cullneu lters, slowly pour the entire contents of two bags of media and enough media from the third bag to raise the
level of media in the tanks to within 21” of the top of the tank.
DO NOT OVERFILL. Overfilling will result in excess media being lost to drain during backwash, possibly plugging the
control valve. Shake the tank to level the media.
Filling Procedure 8