Specifications
Filtr-Cleer
®
Water Filter
The 8” Filtr-Cleer lters are shipped with one media pack and
the 10” Filtr-Cleer lters are shipped with two media packs.
Verify that the proper number of media packs are on site
before loading the tank. Place the manifold inside the tank.
Position the tip of the manifold in the recess located in the
bottom of the tank.
• Cover the top of the manifold with a clean rag.
• Place a wide-mouth funnel in the tank opening.
• Open the media pack(s) by cutting along the bottom of the
carton and lifting up to expose the four individual media
packages. See Figure 2.
Note: The performance of the filter may be severely
affected if the media is not added in the proper sequence
shown.
• With no water in the tank, slowly pour the Cullsan
®
U
media into the tank.
Note: The 10” filter uses only one bag of Cullsan U media
pack. Shake tank to level the media.
• With no water in the tank, slowly pour the Cullsan G-50
media into the tank and level.
Note: The 10: filter requires the Cullsan G-50 from both of the media packs.
• With no water in the tank, slowly pour the Cullsan A media into the tank and level.
Note: The 10” filter requires the Cullsan A from both of the media packs.
• With no water in the tank, slowly pour the Cullcite
®
media into the tank and level.
Note: The 10” filter requires the Cullcite from both of the media packs.
Cullar
®
Filters
Cullar lters are shipped with one cubic foot of carbon and a 20 lb bag of Cullsan underbedding. Verify that the proper amount of
media is on site before loading the tank.
• Place the manifold inside the tank. Position the tip of the manifold in the recess located in the bottom of the tank.
• Cover the top of the manifold with a clean rag.
• Place a wide mouth funnel in the tank opening.
• Open the bag of Cullsan underbedding. On 8” Cullar units, slowly pour approximately half the contents of the bag into the
tank. On 10” Cullar units, pour the entire contents into the tank. Shake the tank to level the media.
• Open the bag of carbon. On 8” Cullar units, slowly pour the carbon into the tank via the funnel until the carbon is within 13”
- 14” of the top of the tank. On 10” Cullar units, slowly pour the entire contents of the bag into the tank. Shake the tank to level
the media.
• Remove the rag from the manifold.
• Fill the tank with water and allow the media to soak for 24-48 hours. The water level in the tank will decrease as the media
soaks up water. Add water to the tank to keep the media submerged so all of the media gets saturated.
Figure 2
7 Culligan Medallist Series
®
Water Filters
Filling Procedure