Specifications

Worksheet
Aqua-Cleer
®
/Good Water Machine
®
System Performance Worksheet
Quality
Feed Water TDS: TDS
FEED
__________
Product Water TDS: TDS
PROD
__________
[(TDS
FEED
- TDS
PROD
) ÷ TDS
FEED
] x 100 = __________% Removal
Quantity Produced
Product Water Flow: F
PROD
___________
Product Water Temperature: T__________
Temperature Correction Factor: TCF________
F
PROD
÷ TCF = __________F
CORR
(Corrected Product Flow)
Feed Water TDS: TDS
FEED
__________
(TDS
FEED
- 500) x 0.014 = __________ P
OS
(Osmotic Pressure)
Feed Water Pressure: P
FEED
__________
P
FEED
- P
OS
= __________ P
EFF
(Effective Pressure)
Read theoretical product flow from figure 13 at effective pressure, compare to corrected product flow.
Theoretical Product Flow: F
THEOR
__________
Quantity Stored
P
Feed Water Pressure: P
FEED
__________
FEED
x 0.60 = __________P
T
(Tank Pressure at Shutoff)
Tank Air Pressure: P
A
__________
Using P
T
and P
A
, read the volume of water stored when the shutoff actuates from figure 14.
Volume Stored: VS __________
Efficiency
Product Water Flow: FPROD __________
Concentrate Water Flow: FCONC __________
FP ÷ (FPROD + FCONC) x 100 = __________ % Recovery
32 Aqua-Cleer
®
/ Good Water Machine
®