Specifications
AC-30 Estimated Flow Rates
Temperature °F
35 40 45 50 55 60 65 70 75 80 85
Feed NDP TCF
2.23 2.03 1.84 1.68 1.52 1.38 1.26 1.14 1.04 0.94 0.86
PSI PCF Product Flow Rate in milliliters per minute
25 20.0 2.5 14.1 15.6 17.1 18.8 20.7 22.8 25.1 27.6 30.4 33.4 36.8
30 25.0 2.0 17.7 19.4 21.4 23.5 25.9 28.5 31.3 34.5 37.9 41.8 45.9
35 30.0 1.7 21.2 23.3 25.7 28.2 31.1 34.2 37.6 41.4 45.5 50.1 55.1
40 35.0 1.4 24.7 27.2 29.9 32.9 36.3 39.9 43.9 48.3 53.1 58.5 64.3
45 40.0 1.3 28.3 31.1 34.2 37.7 41.4 45.6 50.2 55.2 60.7 66.8 73.5
50 45.0 1.1 31.8 35.0 38.5 42.4 46.6 51.3 56.4 62.1 68.3 75.2 82.7
55 50.0 1.0 35.3 38.9 42.8 47.1 51.8 57.0 62.7 69.0 75.9 83.5 91.9
60 55.0 0.9 38.9 42.8 47.1 51.8 57.0 62.7 69.0 75.9 83.5 91.9 101.1
65 60.0 0.8 42.4 46.7 51.3 56.5 62.1 68.4 75.2 82.8 91.1 100.2 110.3
70 65.0 0.8 45.9 50.5 55.6 61.2 67.3 74.1 81.5 89.7 98.7 108.6 119.4
75 70.0 0.7 49.5 54.4 59.9 65.9 72.5 79.8 87.8 96.6 106.3 116.9 128.6
80 75.0 0.7 53.0 58.3 64.2 70.6 77.7 85.5 94.0 103.5 113.8 125.3 137.8
85 80.0 0.6 56.5 62.2 68.4 75.3 82.9 91.2 100.3 110.4 121.4 133.6 147.0
90 85.0 0.6 60.1 66.1 72.7 80.0 88.0 96.9 106.6 117.3 129.0 142.0 156.2
95 90.0 0.6 63.6 70.0 77.0 84.7 93.2 102.6 112.8 124.2 136.6 150.3 165.4
100 95.0 0.5 67.1 73.9 81.3 89.4 98.4 108.3 119.1 131.1 144.2 158.7 174.6
Your measured results are acceptable if within 20% of the figures above.
Estimated flow to the drain should average about the same as the 75 column and should be almost double that flow rate if fed with
hard water above 10 gpg.