Specifications

Service & Maintenance
Service Schedule
To keep the Aqua-Cleer
®
/Good Water Machine
®
system operating properly, it is necessary to change the filters and sanitize the
system periodically. Typically, this should be done on an annual basis. Service frequency may vary depending on local water
conditions. High sediment, chlorine, turbidity, or hardness levels may require more frequent service. Use the following as a guide.
As needed
Clean the faucet with a soft cloth, avoid abrasive cleaners
At least once per year
Replace: • Particle Filter Activated Carbon Filter • Polishing Filter
Check: RO Membrane Capillary Assembly TDS Reduction Performance
Flow Rates (including air gap) Capillary Assembly • Drain tubing for back-up
Sanitize the System
Cartridge Conditioning
The activated carbon, reverse osmosis, and polishing filter cartridges must be conditioned as follows prior to installation into the
Aqua-Cleer/Good Water Machine system. Follow the procedures detailed in the “In-Plant Preparation” section of this manual.
Activated Carbon Cartridge - 5 gallon flush to remove carbon dust
RO Membrane - Minimum 24 hour flush to remove preservative solution
Polishing Filter - 2 gallon flush to remove carbon dust
Materials Needed for Sanitization Procedure
Myron L TDS Monitor (D0470504) 1/4” X 3/8” coupling - JG
1/4” pressure gauge (01004228) with needed fittings 3/8” X 3/8” coupling - JG
Graduated cylinder (00470503) and/or teaspoon measure 1/4” X 1/4” coupling -JG
Pocket Thermometer (00470501) roll of paper towels pan or tray that will hold water
64 oz (1 liter) container with spout for bleach solution empty filter bowl, syringe, eye dropper for injecting bleach
Clorox Ultra bleach with a safe way of dispensing spare parts - tubing o-rings and fittings, faucet stems, etc.
Old water squirt bottle
Service & Maintenance 27