Specifications
Checking Efficiency
Measure and record the product water flow and the concentrate water flow. Calculate the percent recovery as follows:
Product Water Flow
% Recovery = (Product Water Flow + Conc. Water Flow) x 100%
If the concentrate flow rate for the example system is measured at 66 gpd:
22 gpd ÷ (22 gpd + 66 gpd) x 100% = 25% Recovery
Table 3 - Temperature Correction Factors
(77° F [25° C] rating multiplied by correction factor equals capacity)
Feed Water
Temperature
Correction
Factor
Feed Water
Temperature
Correction
Factor
Feed Water
Temperature
Correction
Factor
°F °C °F °C °F °C
36 2 0.33 52 11 0.56 68 20 0.83
38 3 0.34 54 12 0.59 70 21 0.87
40 4 0.37 56 13 0.63 72 22 0.90
42 6 0.40 58 14 0.65 74 23 0.94
44 7 0.43 60 16 0.69 76 24 0.96
46 8 0.46 62 17 0.72 77 25 1.00
48 9 0.50 64 18 0.76 78 26 1.03
50 10.0 0.52 66 19 0.79 80 27 1.06
Graph 2
Graph 3
Graph 4
24 Aqua-Cleer
®
/ Good Water Machine
®