Specifications

Single basin sink without disposal:
Connect the RO outlet to the tailpiece directly beneath the sink.
If a dishwasher drain connection is present, the RO outlet must be connected above it.
Single basin sink with disposal:
Connect the RO outlet to the dishwasher drain port on the disposal if available.
If the dishwasher drain port is not available, other arrangements must be made such as running the RO outlet to a basement
sump.
Do not connect the RO outlet to the plumbing below the disposal.
Double basin sink with disposal, single trap:
The fitting which joins the drains from the disposal and second sink should be directional. If not, then Culligan recommends
that it be replaced.
Connect the RO outlet to the tailpiece just below the second sink.
If a dishwasher drain is present and cannot be relocated, the RO outlet must be connected above it.
Do not connect the RO outlet to the horizontal plumbing between the two sink drains.
Double basin sink with disposal, double trap:
Connect the RO outlet to the tailpiece just below the second sink.
If a dishwasher drain is present and cannot be relocated, the RO outlet must be connected above it.
Reservoir Tank Placement
Place the reservoir tank in the location previously selected.
Install Filter System Assembly
The mounting bracket contains two mounting slots. The holes are sized to accept #10 round head wood screws (not supplied).
Some types of surfaces such as particle board or drywall, may require the use of plastic screw anchors or toggle bolts to provide
adequate support for the unit.
Using the mounting bracket as a template, mark the two mounting screw locations.
Drill a 1/8-inch hole at each mounting screw location.
Thread a wood screw into each of the holes, leave a 1/2-inch space between the screw head and the mounting surface.
Hang the bracket on the mounting screws and tighten.
Connect System
When cutting plastic tubing, use a sharp razor blade. Cut the tubing squarely.
1. Connect 1/4-inch OD plastic tubing from the feed water supply source to the system inlet on the manifold.
2. Connect the product water outlet on the manifold to the storage tank valve using 3/8” OD plastic tubing.
3. Connect the 3/8” OD product water tube from the faucet to the outlet of the polishing filter.
4. Connect the product water outlet on the manifold to the inlet of the polishing filter using 3/8” OD plastic tubing.
5. Connect the 1/4” OD tubing from the air gap inlet of the faucet to the concentrate outlet on the manifold (capillary assembly).
6. If an icemaker is to be installed, a tee must be installed between the manifold and the tank.
7. Place the filter assembly onto the mounting bracket.