Specifications

Installation
The exact placement of the components will vary by installation. Although shown beneath a sink, it may be installed in a
basement, crawl space, or in an adjacent cabinet. Regardless of where the system is installed, the flow sequence described by
(Figure 7) must be observed.
The Aqua-Cleer
®
/Good Water Machine
®
drinking water system is designed to be mounted near a sink for easy access to cold water
and drain lines. Lengths of 1/4-inch and 3/8-inch OD plastic tubing will be required to make this installation. A length of Culligan
®
drain tubing is required to install the air gap siphon break.
Evaluate the installation site to determine the easiest path for the plumbing to follow. Take care to make the installation as neat as
possible.
Aqua-Cleer
Faucet
Monitor
Sensor
Drain
Tubing From
Faucet Air Gap
- 3/8” Tubing
Cold Water
Supply
Monitor
Post
Filter
3/8" Tubing
to Faucet
Product
Port
1/4" Tubing
to Faucet
Air Gap
Feed Line
1/4" Tubing
AC-30
Manifold
Ball Valve
3/8" Tubing to Faucet Product Port
Tank
Figure 7
NOTICE: Install the drain line so that it runs downward with no loops or low spots. Otherwise the unit will overflow at the air
gap siphon break built into the faucet, or make irritating gurgling sounds. The concentrate line that leads to the faucet should be
installed in a straight vertical path to avoid making a gurgling noise.
Installation 11