Specifications

Theservicemodeallowsonetoviewtheinstantaneousowrate,thegallonsremainingbeforethe
softenersignalsforregeneration,thenumberofregenerationsinthepast14days,thetotalnumber
of regenerations the control has cycled through and the number of days since the last regeneration.
The statistical functions are reached by pressing the “Status” key until the screen blanks and then
pressingthe“-”key.Repetitivepressesofthe“-”keywillcyclethroughthestatisticsmode.Pressing
the “Status” key will exit statistics and move to the time display. The following table outlines the
statisticfunctiondisplay,rangelimitsanddefaultsetting:
Display Range Limits Comments
Flow Rate 0to999.0 Basedon“K”factorsetting,updatedaminimum
of every 6 seconds (Only active with Flow Meter
attached).
•Capacity Remaining
(gal / L) (Meter Mode)
0-9,999 Remaining gallons (liters) until batch capacity is
reached.Updatedisplayaminimumofevery6
seconds (Only active with Flow Meter attached).
• Number of
Regenerations-Last14
days
0to99 -Dayscounteristobeupdatedat12:00AMONLY
when dip #2 is on ANDdip#4isoff;Otherwise
updateatwhateverTORissetfor
-NumberofRegenerationistobeupdatedaftera
valid regeneration is complete (cycle 3 times out
automatically)
• Number of days since
last Regeneration
0to99 -Dayscounteristobeupdatedat12:00AMONLY
when dip #2 is on ANDdip#4isoff;Otherwise,
updateatwhateverTORissetfor
-Afteravalidregenerationiscomplete(cycle3times
outautomatically),thecounteristoberesetto0
• Number of
Regenerations-Lifeof
theUnit
0to9,999 Counter is to be updated after completion of valid
regeneration cycle (cycle 3 times out automatically)
•TobesavedinEEPROMbeforethecontrolispowereddownduringapoweroutage.
Oncethestatisticsmenuisenteredtheinformationshownforeachdisplayisoutlinedbelow:
“Regen” key is always ignored in statistics mode;
Canenterdirectlyintodiagnosticsmodebypressingthe“+”key;
Whenreturningtostatisticsmodedirectlyfromdiagnosticsmode,alwaysdisplaytherst
statisticinthelistasifstatisticsmodewasenteredforthersttime(don’thavetoremember
where it left off in the list);
Can exit back to service mode by pressing the “status” key;
Automaticallytimesoutbacktoservicemodeafter10minutesofnokeypressactivity-
EXCEPTfor“owrate”and“capacityremaining”;whendisplaying“owrate”and“capacity
remaining”thecontrolcanstayinstatisticsmodeindenitely;
Drop all leading zeros;
Service Check
20