Specifications

Inside Text
18
Regeneration Interval (Time
Clock Mode)
This setting is used to set the days between
regeneration in time clock mode. The display
will show “REG” icon and “dAY” for two
seconds and then display the numbers to
change.Adjustthevaluewiththe“+”or“-”
keys.
Pressing the “Status” key will save the setting
and move to the next programming step.
Regeneration Interval (Time
Clock Back-up)
This setting is used to set the days between
regenerationwhentimeclockback-upis
activated in a meter mode. It is activated in
meter mode if the time clock backup DIP
switch #4 is set to on. The display will show
the REG icon and tcb” for two seconds and
then the number of days. Adjust the value
withthe“+”or“-”keys.Pressingthe“Status”
key will save the setting and move to the next
programming step.
Salt Dosage
This settings used to set the salt dosage.
Thedisplaywillrstshow“SLtP”(SLtGfor
metric according to DIP switch #5 setting) for
two seconds and then display the default (or
previously programmed value). Adjust the salt
dosagewiththe“+”or“-”keys.
Pressingthe“STATUS”keywillsavethe
setting and move to the next programming
step.
Backwash Time
Thissettingisusedtoprogramthecycle1time
that is usually backwash. The time of the cycle
is kept in minutes. The display will show “buu”
in the display for two seconds and then the
cycle time in the right most digits. Adjust the
valuewiththe“+”or“-”keys.
Pressing the “Status” key will save the setting
and move to the next programming step.
Programming
(cont.)