Specifications
17
Programming
Thetimerusesfourbuttons:
Button Description
Set-up/EnterKey(Status)
Advance timer through display options
Regeneration Key (REGEN) Initiate a regeneration
ToggleDownKey(“-”)
Decrease the setting
ToggleUpKey(“+”)
Increase the setting
Time of Day
This setting is used to program the current time
ofday.Wheninthisstepthedisplaywillrst
show “tod” for two seconds.
After“tod”isdisplayed,“12:00PM”willdisplay
(or the current set time if already programmed)
andtheminuteswillash.
• The minutes are adjusted with the
“+”or“-”keyuntilthecorrectvalueis
displayed.
•Pressthe“Regen”keytoashthe
hours.Adjustwiththe“+”or“-”key
until the correct time is displayed.
Pressing the “Status” key will move to the next
programming step. Pressing “Regen” will move
back to the minutes adjust.
Time of Regeneration
This setting is used to program the time at
which a regeneration is to occur in the delay
mode, or in immediate mode with time clock
backupon.Thedisplaywillrstshow“tor”for
two seconds.
After “tor” is shown the display will then
showthedefaultof2:00AM(orthecurrent
programmed time of regeneration if already
set).Thetimecanbeadjustedin30minute
incrementsbypressingthe“+”or“-”keys.
Pressing the “Status” key will save the setting
and move to the next programming step.