Specifications
Table3-MaximumAllowableDrainLineLength
Height of Discharge Above Floor Level Operating
Operating
Pressure
0 ft (0 m) 2 ft (0.6 m) 4 ft (1.2 m) 6 ft (1.8 m) 8 ft (2.4 m) 10 ft (3 m)
30 psi
(210 kPa)
60ft(18m) 50ft(15m) 30ft(9m) 15ft(5m)
Not allowable Not allowable
40 psi
(279 kPa)
100ft(30m) 90ft(27m) 70ft(21m) 50ft(15m) 30ft(9m) 12ft(4m)
50 psi
(349 kPa)
145ft(41m) 115ft(35m) 80ft(24m) 80ft(24m) 60ft(18m) 40ft(12m)
60 psi
(419 kPa)
Normal installation 100ft(30m) 100ft(30m) 85 ft (26 m) 60ft(18m)
80 psi
(559 kPa)
Should not require more than 140ft(43m) 120ft(37m)
100 psi
(699 kPa)
100ft(30m)ofdrainline 150ft(46m)
Themicroprocessorcanbesetintwodistinctoperationmodes,Soft-Minder
®
meter or Timeclock.
As shipped from the factory, the control is set for 8” Timeclock operation.
Soft-Minder
®
Operation
TheSoft-Mindermeterutilizesaturbineimpellertoaccuratelymonitorthecustomerswaterusage.
After a predetermined amount of water has passed through the system, the microprocessor will
signal a regeneration. The “REG” enunciator will light at this point. The unit will perform a standard
regeneration cycle at the preset time, unless the programming option “dip 2” is changed from “DEL”
to “Id”. When programming option “dip 2” is changed from “DEL” to “Id”, a regeneration will begin
immediately.
TheprogrammingoftheSoft-Minderprovidesseveralsettablevariables,theTime-of-Day,Time-of-
Regeneration,SaltDosage,BackwashTime,Brine/RinseTime,GallonstoSignalandTimeclock
Backup,ifactive.Refertotheprogrammingsectionforfurtherinformationonprogrammingthe
microprocessor.
Time Clock Operation
Whenthemicroprocessorisset-upasatimeclockunit,theCulliganMedallistSeries
™
control will
regenerateatxedintervals.Theregenerationintervalcanbesetanywherefrom1to99days.
TheprogrammingforthetimeclockmodelsislimitedtoTime-of-Day,Time-of-Regeneration,Salt
dosage,BackwashTime,Brine/RinseTime,andtheRegenerationInterval.Refertotheprogram-
ming section for further information on programming the microprocessor.
16
Installation
(cont.)