Specifications

Table3-MaximumAllowableDrainLineLength
Height of Discharge Above Floor Level Operating
Operating
Pressure
0 ft (0 m) 2 ft (0.6 m) 4 ft (1.2 m) 6 ft (1.8 m) 8 ft (2.4 m) 10 ft (3 m)
30 psi
(210 kPa)
60ft(18m) 50ft(15m) 30ft(9m) 15ft(5m)
Not allowable Not allowable
40 psi
(279 kPa)
100ft(30m) 90ft(27m) 70ft(21m) 50ft(15m) 30ft(9m) 12ft(4m)
50 psi
(349 kPa)
145ft(41m) 115ft(35m) 80ft(24m) 80ft(24m) 60ft(18m) 40ft(12m)
60 psi
(419 kPa)
Normal installation 100ft(30m) 100ft(30m) 85 ft (26 m) 60ft(18m)
80 psi
(559 kPa)
Should not require more than 140ft(43m) 120ft(37m)
100 psi
(699 kPa)
100ft(30m)ofdrainline 150ft(46m)
Themicroprocessorcanbesetintwodistinctoperationmodes,Soft-Minder
®
meter or Timeclock.
As shipped from the factory, the control is set for 8” Timeclock operation.
Soft-Minder
®
Operation
TheSoft-Mindermeterutilizesaturbineimpellertoaccuratelymonitorthecustomerswaterusage.
After a predetermined amount of water has passed through the system, the microprocessor will
signal a regeneration. The “REG” enunciator will light at this point. The unit will perform a standard
regeneration cycle at the preset time, unless the programming option “dip 2” is changed from “DEL”
to “Id”. When programming option “dip 2” is changed from “DEL” to “Id”, a regeneration will begin
immediately.
TheprogrammingoftheSoft-Minderprovidesseveralsettablevariables,theTime-of-Day,Time-of-
Regeneration,SaltDosage,BackwashTime,Brine/RinseTime,GallonstoSignalandTimeclock
Backup,ifactive.Refertotheprogrammingsectionforfurtherinformationonprogrammingthe
microprocessor.
Time Clock Operation
Whenthemicroprocessorisset-upasatimeclockunit,theCulliganMedallistSeries
control will
regenerateatxedintervals.Theregenerationintervalcanbesetanywherefrom1to99days.
TheprogrammingforthetimeclockmodelsislimitedtoTime-of-Day,Time-of-Regeneration,Salt
dosage,BackwashTime,Brine/RinseTime,andtheRegenerationInterval.Refertotheprogram-
ming section for further information on programming the microprocessor.
16
Installation
(cont.)