Specifications

Installation
(cont.)
15
Soft-Minder
®
Meter Connection
ToconnectthemeterleadsrefertoFigure20andproceedasfollows:
Lift up the timer case from
the back plate.
Remove the small plastic
plug from the backplate.
Slip the meter harness
through the hole and
toward the circuit board.
Connect the harness to
the circuit board. The
Soft-Minder
®
meter
terminal is labeled
“FLOWMETER”.
Pull any excess cable
wire back out of the
enclosure, and route
the wiring inside the
enclosure to avoid any
interference with moving
parts.
Locate the strain relief
bushing in the parts pack.
Place it on the cable at
the point of entry to the
rear of the timer plate and
push it into the hole.
Electrical Connections
Thepowercordneedstobeconnectedtotheplug-in
transformer,wireorientationisnotcritical.Figure21shows
the cord attachment to the transformer. Connect wire
harnessto24VACterminalsontransformer.
Note: Observe all state and local electrical codes.
Note: The plug-in transformer is rated for indoor
installations only.
Note: The wire connectors must be connected to the circuit board properly. The wires must exit
the plug-in connector opposite of the raised white base of the circuit board connector. Failure to
properly connect any of the connectors will result in a malfunction of the circuit board operation.
Figure20