Specifications

Installation
(cont.)
13
Bypass Valve
Installation - 1”
Medallist
Plus Units
The bypass valve connects directly
to the control valve with a pair of
couplings and two assembly pins
(Figure16).Lubricateallo-rings
on the couplings with silicone
lubricant.OnSoft-Minder
®
meter
controls, the meter replaces the
coupling on the outlet side of the
control.Themeterbodytsin
the same space as the coupling
between the control valve and the
bypass. Make sure that the arrow
ontheowmeterispointinginthe
directionofow(Figure16).
Note: If the ground from the electrical panel or breaker box to the water meter or underground
copper pipe is tied to the copper water lines and these lines are cut during installation of the
bypass valve, an approved grounding strap must be used between the two lines that have been
cut in order to maintain continuity. The length of the grounding strap will depend upon the number
of units being installed. In all cases where metal pipe was originally used and is later interrupted
by the bypass valve to maintain proper metallic pipe bonding, an approved ground clamp c/w not
less than #6 copper conductor must be used for continuity. Check your local electrical code for the
correct clamp and cable size.
To bypass, turn the blue knob clockwise (see directional arrow on end of knob) until the knob
stopsasshown.DONOT
OVERTIGHTEN!(Figure17a).
To return to service, turn the
blueknobcounter-clockwise
(see directional arrow on the
end of knob) until the knob
stopsasshown.DONOT
OVERTIGHTEN!(Figure17b)
Drain Line Connection
Refertopage16fordrainline
length and height limitations.
• Remove1/2”pipeclampfrom
the small parts pack included
with the control.
• Routealengthof1/2”drain
line from the drain elbow to
the drain.
Fasten the drain line to the
elbow with the clamp.
Secure the drain line to
prevent its movement
during regeneration. When
discharging into a sink,
About 1-1/4”
A screwdriver shank may be
used in the slot as a lever for
extra turning force if needed.
Figure17b
Figure17a
Bypass
Assembly Pin
Coupling
or Meter Body
Coupling
Assembly
Pin
Brine
Connection
Figure16