Specifications
Installation
(cont.)
11
Unit Backwash Flow Nozzle Throat Brine Refill Flow
8” #1,Black* Blue* LightBrown* 0.45gpm
Medallist30 #2,Brown*
Blue* LightBrown* 0.45gpm
Medallist 45 #2,Brown
@6lbs-Blue
Greater than
6lbs-Beige
LightBrown 0.45gpm
Medallist60
#3, Green Beige LightBrown 0.8gpm
*Standardfromfactory.
Refertogure13foravisualonchangingthe
eductornozzleandthebackwashowcontrol.
Eductor Nozzle Replacement:
• Remove the three screws on the eductor cap
and remove the cap.
• Remove the eductor assembly.
• Remove the eductor screen from the assembly
• Remove the blue nozzle and replace it with the
beigenozzle.Makesuretoputtheo-ringon
the beige nozzle.
• Reverse the procedure to reassemble. To
prevent leaks, ensure that the gasket is in the
proper position.
Backwash Flow Control
Replacement:
• Remove the drain clip and pull the drain elbow straight off.
• Removethebackwashowcontrollocatedbehindtheelbow.
Note: The number on the flow control should face into the valve body.
• Reverse the procedure to reassemble.
Plumbing Connections
General Instructions
• Follow local plumbing & electrical codes. Failure to do so may result in your having to redo the
installation at your expense.
• Takethetimetomakeaclean,professionallookinginstallation.Useuxandsoldersparingly
when making sweat connections, and avoid excessive use of pipe compound. When using
galvanized pipe, clean out excess cutting oil and metal chips before assembly. Foreign objects,
if allowed to enter the control valve, can cause operating problems.
• The main water supply line may then be reopened so that hard water will be available to the
householdthroughouttheremainderoftheinstallationprocess.SettheCul-Flo-ValveBypassin
the bypass position by screwing the stem all the way in against the body.
Caution! Close the inlet supply line and relieve system pressure before cutting into the
plumbing! Flooding could result if not done!
Figure13