Specifications

3. Removethetwou-clampsandscrewsfromtheparts
pack. Install the clamps on both sides of the control
asindicatedinFigure10andsecurethemwiththe
screws.
4. Peelofftheprotectivelmoffthecircuitboardlabel.
5. Attach the appropriate Culligan Medallist Series data
plate that’s included in the small parts pack onto
the back of the control (over the holes used for the
solenoid valve).
Mount The Control Valve - 1” Control
SeeFigure11foravisualonmountingthecontrolvalve
to the tank.
• Assembletheo-rings,locatedinthepartspack,to
the tank adapter.
• Thevalveadaptero-ringsitsontherst
stepontheadapter.SeeFigure12.
Note: Do not push the top o-ring down to
the ange surface on the adapter.
Note: The larger of the two o-rings in the
parts part goes between the adapter and
the valve, do not stretch the smaller o-ring
onto the top of the tank adapter.
• Lubricateonlythetopo-ringonthetank
adapter,andtheoutletmanifoldo-ringwith
silicone lubricant.
Screw the adapter into the tank until the
adapterbottomsoutonthetankange.
Note: The adapter only needs to be
tightened hand-tight to the tank flange.
Align the manifold with the center opening
in the valve, and press the valve onto the
adapterrmly.
Note: Make sure to push the valve straight
down onto the manifold. If the valve is
cocked, it may cause the o-ring to slip off
the manifold.
Assemble the tank clamp to the control,
and tighten the clamp screw.
Note: The clamp and valve will be able to
rotate on the tank until pressure is applied.
Do not try to rotate control valve if the
clamp is tightened - you may cut the o-ring.
Installation
(cont.)
10
Figure10
Figure12
Figure11