Specifications
Installation
9
Placement
Refer to Figure 9 for system placement.
• Set the media tank on a solid, level surface near water, drain and electrical facilities. Place the
outlet (black coupling) of the tank on the left.
• Setthebrinesystemonaat,smooth,solidsurfaceasnearthemediatankaspossible.
Mount The Control Valve - 3/4” Control
Seegure10foravisualonmountingthecontrolvalvetothetank.
As shipped from the factory the Culligan Medallist Series
®
3/4” control is equipped as a 8” unit.
1. RemovethetwoplasticcapsfromthetankcouplingsandlubricatethecouplingO-ringswith
silicone lubricant.
2. Thecontrolvalveismarkedalsowith“IN”and“OUT”.Placethecontrolontothetankwiththe
inletandoutletofthecontrolcorrespondingwiththeinletandoutletofthetank.Pressrmlyonto
the couplings.
Figure 9
Note: Do not use a petroleum base lubricant, for this will cause swelling of the rubber parts.
Note: The black molded tank adapter is marked with “IN” and “OUT”, corresponding to
the inlet and outlet of the tank. Position the tank with the inlet coupling on the right and the
outlet coupling on the left as you face the front of the tank.