Specifications
System
Specifications
Dimensions - Filter Assembly .............7.5”W x 3”D x 16.5”H
- Storage Tank - Std ..........9” Diameter x 14”H
- Medium ....................11” Diameter x 14”H
- Large .......................15.5” Diameter x 24”H
Storage Capacity - Standard Tank ..............2 gallons
- Medium Tank ...............3 gallons
- Large Tank..................9 gallons
System Flow Sequence ........................Particle Filter, Activated Carbon Filter,
..............................Reverse Osmosis Membrane Filter, Storage
Tank,
..............................Polishing Filter, Dispensing Faucet
Particle Filter ..............................5 Micron Spun Polypropylene
Activated Carbon Filter ........................Solid Carbon Block
Reverse Osmosis Membrane Filter ............. Culligan Aqua-Cleer
®
Thin Film Composite
Polishing Filter ..............................Cullar G Activated Carbon
Dispensing Faucet. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Culligan Aqua-Cleer Faucet Rotary Operation,
Stainless Steel and Resin Flow Passages, with
Built-in Siphon Break
Colors ..................................... Polished Chrome or White
Model 2 Gallon 3 Gallon 9 Gallon
System DPR* to Storage
Tank
14.5 (54.88 L) 14.5 (54.88 L) 14.5 (54.88 L)
Efficiency Rating
3
17.9% 17.9% 17.9%
Recovery Rating4 30.8% 30.8% 30.8%
* DPR - Daily Production Rate
Product Production Rate without storage tank to atmosphere1
- AC-30 Models...............30 gpd (114 L/day)
Ratio of Product to Flush Flow2
Soft Water Applications ...... 2:3
Hard Water Applications...... 1:3 - 1:5
1
Rating at 50 psi, 77°F, 500 mg/L TDS Influent, Without Storage Tank to atmosphere. This is a factory
specification for membrane production. Actual production rate and TDS rejection will depend on temperature,
water pressure, TDS level, membrane variation and usage pattern.
2
May vary with pressure. See Technical Manual for all hard water applications and applications where TDS
exceeds 1000 mg/L (ppm).
3
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse
osmosis treated water under operating conditions that approximate typical daily usage.
4
Recovery rating means the percentage of the influent water to the membrane portion of the system that is
available to the user as reverse osmosis treated water when the system is operated without a storage tank or
when the storage tank is bypassed.
2