Specifications
Performance
Data Sheet
(cont.)
Output (Total Dissolved Solids (TDS) Reduction and Output Production)
1
Tank Size 2 Gallon 3 Gallon 9 Gallon
Product system daily prod. rate to pressurized storage tank 14.5 gpd (54.8 L) 14.5 gpd (54.8 L) 14.5 gpd (54.8 L)
Prod. rate w/o storage tank to atmosphere 30 gpd 30 gpd 30 gpd
Efficiency rating
2
17.9% 17.9% 17.9%
Recovery rating
3
30.8% 30.8% 30.8%
Influent challenge concentration (mg/L) 750 +/- 40 mg/L 750 +/- 40 mg/L 750 +/- 40 mg/L
Max. permissible product water concentration (mg/L) 187 187 187
Minimum percent removal 76.6% 76.6% 76.6%
Average percent removal 81.6% 81.6% 81.6%
1
This is a factory specification for membrane production. Actual production rate and TDS rejection will depend on temperature,
water pressure, TDS level, membrane variation and usage pattern.
2
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated
water under operating conditions that approximate typical daily usage.
3
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user
as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Testing Conditions (Complete Systems)
Temperature: 77° F ± 2° F pH: 7.5 ± 0.5
Pressure: 50 psi Turbidity: < 1 NTU
This system has been tested and shown to operate at its calculated recovery rating under
standard test conditions.
Dimensions
Filter Assembly 7.5” W x 3” D x 16.5” H (20 cm W x 8 cm D x 42 cm H)
Storage Tank Standard 9” Diameter x 15” H (23 cm Diameter x 38 cm H)
Medium 11” Diameter x 15” H (28 cm Diameter x 38 cm H)
Large 15.5” Diameter x 22” H (40 cm Diameter x 56 cm H)
The Good Water Machine models listed above have been tested and
certified by WQA according to NSF/ANSI 372, and CSA B483.1, and NSF/ANSI
Standard 58 for the effective reduction of TDS, Barium, Cadmium, Hexavalent
and Trivalent Chromium, Lead, Radium 226/228, Copper and Selenium as
verified and substantiated by test data. The concentration of the indicated
substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as
specified in NSF/ANSI 58.
Refer to your Installation and Operating Instructions and printed limited Warranties for
more specific product information. To avoid contamination from improper handling and
installation, your system should only be installed and serviced by your Culligan Man.
Performance will vary based on local water conditions. The substances reduced by this
system are not necessarily in your water.