Specifications

22 / AQUA-CLEER
®
/GOOD WATER MACHINE
DRINKING WATER SYSTEMS
6. Remove the filter cartridge with a downward twisting
pull.
7. Clean the inside of the housing.
8. Lubricate the cartridge o-ring with water and insert the
new filter cartridge into the manifold.
9. Pour: two tablespoons liquid chlorine bleach or 3 ounces
hydrogen peroxide into the particle filter housing.
10. Assemble the housing to the manifold and replace the
u-clip.
11. Repeat steps 4-7 and remove the activated carbon
cartridge
and, if using chlorine bleach, the RO
membrane filter .
12. Assemble the empty housing(s) to the manifold and
replace the u-clip(s).
NOTICE: When replacing the RO membrane filter housing,
be sure the drain adaptor is in place.
13. Turn on the supply valve and allow the system to fill
with water. Once water begins to drip or flow from the
faucet, close the faucet and allow the tank to fill.
14. Turn off the supply valve and allow the system to sit for
ten minutes.
15. Open the dispenser faucet and drain the storage tank.
16. Repeat steps 4,5,8 and 10 for replacement of the
activated carbon and RO membrane filter
cartridges.
17. Check the performance of the system according to the
procedure outlined in the “Performance and Technical
Information” section of this manual. Replace the RO
membrane filter if necessary.
18. Remove the capillary assembly from the manifold and
inspect for signs of clogging. Replace if required.
19. If using hydrogen peroxide, disconnect the storage tank
tube from the manifold. With an eyedropper or similar
device, inject one tablespoon of hydrogen peroxide into
the tube and reconnect it to the manifold.
20. Note the direction of flow and disconnect the tubing
from the polishing filter.
21. Note the direction of flow and install the new polishing
filter.
22. Replace the filter assembly onto the mounting bracket.
23. Repeat step 13.
24. After the tank has filled (3-4 hours), open the faucet and
drain the storage tank to flush the new postfilter and any
remaining sanitizing solution from the system.
25. Allow the system to refill. Your system is now ready for
use.
26. Record your service on the chart at the end of the Owners
Guide.
FIG. 15
FIG. 16