Specifications
INSTALLATION / 15
• Do not connect the RO outlet to the horizontal plumb-
ing between the two sink drains.
Double basin sink with disposal, double trap:
• Connect the RO outlet to the tailpiece just below the
second sink.
• If a dishwasher drain is present and cannot be
relocated, the RO outlet must be connected above it.
Reservoir Tank Placement
Place the reservoir tank in the location previously selected.
Install Filter System Assembly
The mounting bracket contains two mounting slots. The
holes are sized to accept #10 round head wood screws (not
supplied). Some types of surfaces such as particle board or
drywall, may require the use of plastic screw anchors or toggle
bolts to provide adequate support for the unit.
• Using the mounting bracket as a template, mark the
two mounting screw locations.
• Drill a 1/8-inch hole at each mounting screw location.
• Thread a wood screw into each of the holes, leave a
1/2-inch space between the screw head and the mount-
ing surface.
• Hang the bracket on the mounting screws and tighten.
Connect System
When cutting plastic tubing, use a sharp razor blade. Cut the
tubing squarely.
1. Connect 1/4-inch OD plastic tubing from the feed water
supply source to the system inlet on the manifold.
2. Connect the product water outlet on the manifold to
the storage tank valve using 3/8" OD plastic tubing.
3. Connect the 3/8" OD product water tube from the faucet
to the outlet of the polishing filter.
4. Connect the product water outlet on the manifold to
the inlet of the polishing filter using 3/8" OD plastic
tubing.
5. Connect the 1/4" OD tubing from the air gap inlet of the
faucet to the concentrate outlet on the manifold l
(capillary assembly).
6. If an icemaker is to be installed, a tee must be installed
between the manifold and the tank.
7. Place the filter assembly onto the mounting bracket.
Start-Up
The following procedure should be performed during the plant
pre-delivery check out and again after installation:
• Turn on the inlet feed water valve and open the tank
valve.
• Check system thoroughly for leaks.
• Run product water from faucet to flush carbon dust
out of the carbon postfilter.
• Verify proper module performance.
Overall System Check
• Turn on the inlet feed water valve and open the tank
valve. A complete systems check can be performed
when the reservoir tank has been precharged with
water.
• Move the faucet lever to the full open position. A
steady stream of product water should be observed if
the tank was filled earlier.
• Make a complete system check and adjust as needed
to correct any leaks.
• Run product water through the faucet to flush out any
remaining carbon dust from the post filter.
• Perform a final module check to verify proper
product performance.
• Thoroughly clean up the equipment and the
installation site.
Review Operation With Customer
Review the operation of the Culligan
®
drinking water
system with the customer. Explain that the unit will require
routine maintenance of the prefilters, reverse osmosis mem-
brane filter, and the polishing filter. Advise the customer how
often these items will need to be serviced based on your past
experience. Discuss the product and module warranties.