Specifications

5
01023052
Culligan High Efciency Twin SoftenerUpow Regeneration
Model 9" Model 10" Model
Control Valve 1” Reinforced Thermoplastic with HE Circuit Board
Overall Conditioner Height 56 in 62 in
Media Tank Design Quadra-Hull
Media Tank Dimensions (Dia x Ht) 9 x 48 in 10 x 54 in
Salt Storage Tank Dimensions (Dia x Ht) 18 x 43 in
Exchange Media, Type and Quantity Cullex
®
Media, 1.0 ft
3
Cullex Media, 1.5 ft
3
Underbedding, Type and Quantity Cullsan
®
Underbedding, 12 lb Cullsan Underbedding, 15 lb
Exchange Capacity @ Salt Dosage Per Recharge
17,854 gr @ 4.0 lb 26,781 gr @ 6.0 lb
27,108 gr @ 8.0 lb 40,662 gr @ 12.0 lb
31,736 gr @ 12.0 lb 47,604 gr @ 18.0 lb
Efficiency rated dosage
1
4,463 gr/lb @ 4 lb salt dosage 4,463 gr/lb @ 6 lb salt dosage
Proportional Brining Efficiency Rating
2
5,250 gr/lb @ 4 lb salt dosage 5,247 gr/lb @ 6 lb salt dosage
Freeboard to Media
3
14.5 in 14.5 in
Freeboard to Underbedding
4
44.5 in 47.5 in
Salt Storage Capacity 375 lb
Rated Service Flow @ Pressure Drop 9.0 gpm @ 11 psi 9.4 gpm @ 12 psi
Auxiliary Flow Rate
5
10.8 gpm @ 15 psi 11.3 gpm @ 15 psi
Total Hardness, Maximum 30 gpg
Total Iron, Maximum 2 ppm
Hardness to Iron Ratio, minimum 8 gpg to 1 ppm
Operating Pressure 20-125 psi [138–862 kPa]
Operating Pressure (Canada) 20-90 psi [138621 kPa]
Operating Temperature 33-120°F [049°C]
Electrical Requirements 24V/60 Hz
Electrical Power Consumption, Min/Max 8.4 watts/21.6 watts
Drain Flow, Maximum
6
2.5 gpm
Recharge Time, Average
7
Recharge Water
78 minutes 67 minutes
Consumption, Average
7
47 gallons 45 gallons
1 The efciency rated dosage is only valid at the stated salt dosage and is efciency rated according to NSF/ANSI 44.
2 The Proportional Brining Efciency Rating assumes a 20 percent reserve capacity at the time of regeneration that is typical
of what the manufacturer expects under real-world operation. Proportional brining is not measured by NSF/ANSI 44, and
so this cliam is not, and can not, be rated to NSF/ANSI 44.
3 Measured from top of media to top surface of tank threads. (backwashed and drained).
4 Measured from top of underbedding to top surface of tank threads.
5 Auxiliary ow rates do not represent the maximum service ow rate used for determining the softener’s rated capacity and
efciency and that continuous operation at these ow rates greater than the maximum service ow rate may affect capacity
and efciency performances.
6 Backwash at 120 psi (830 kPa).
7 10 minute backwash, 4 lb. 9” model, 6 lb. 10” model, 7 lb. 12” model, or 12 lb. 14” model salt dosage