Specifications
29
01023052
CAUTION! Verify wiring from the terminals to circuit board are
correct before applying power to the control. 24
VAC power must not be applied to the 2.5 VAC ter-
minals of the circuit board. Connecting 24 VAC to the
2.5 VAC connection on the circuit board will damage
the circuit board.
2.5V
METAL TABS
Connect to white
connector on main
power cord
24VAC
on TRANSFORMER
Power to circuit
board 2.5VAC
only required
for Aqua-Sensor
installations
Power to circuit
board 24V
Red
Black
Blue
White
PHONE
Figure 22. 2.5 VAC Aqua-Sensor
®
power connection.
12. Reattach the electrical enclosure cover to the control valve.
a. Align the circuit board in the enclosure with the three support brackets on the con-
trol valve frame. See Figure 23.
b. Push the enclosure onto the control valve, inserting the circuit board edge in the
slots on the control valve frame and the screw on the enclosure with the hole on
the cover.