Specifications
21
01023052
A
Cover
Fastener
Push down
into place
Figure 12. Reattaching the cover fastener.
Dial-a-Softness
Dial-a-Softness is a manual adjustment
built into the control valve that allows
for variable hardness bypass into the
softened water. The hard water bypass
can be adjusted to produce 1–3 gpg
hardness bleed. Shipped from the
factory the Dial-a-Softness knob is set to
the “SOFTEST” position (no hard water
bypass). See Figure 13.
To set the Dial-a-Softness:
1. Locate the Dial-a-Softness knob
on the control valve.
2. Set the Dial-a-Softness knob to position A, B, or C as outlined in the table below, based on
raw water hardness; this should produce a 1–3 gpg hardness bleed.
Letter on Dial-a-Softness Knob 1–3 gpg Hardness Bleed
SOFTEST 0
A Greater than 20 gpg
B Between 10–20 gpg
C Less than 10 gpg
NOTE The HE must take into account the adjusted capacity if the Dial-a-Softness
was changed.
Figure 13. Dial-a-Softness knob.