Specifications

16
01023052
Load the Tank (12” and 14” Tanks)
1. Position the tank so that the Culligan® logo is in the front.
2. Remove the inlet strainer.
3. Install the outlet manifold into the tank (Figure 2).
4. Cover the tops of the manifolds with a clean rag.
5. Using a large-mouth funnel, load the Culligan underbedding through the top of the tank.
CAUTION! DO NOT allow the outlet manifold to move when loading
the media. The manifold must remain vertical to ensure a
good seal at the gasket. Rap the tank near the bottom with
a rubber mallet to level the sand.
6. Load the tank with the Cullex® ion exchange resin. Leveling
is not required.
7. Remove the funnel.
8. Install the inlet strainer making sure to thread the strainer until
it bottoms out on the tank thread. Failure to install the strainer
correctly can cause the cotrol to leak.
Aqua-Sensor
®
Installation
1. Measure the sensor cable length: refer to Figure 2 and Table
1 (the Aqua-Sensor cord is set at the factory for a 9” tank).
Tank Model Dimension X Y
9” Quadra-Hull™ Tank 34 1/2" 40"
10” Quadra-Hull Tank 30 1/2" 44"
12” Quadra-Hull Tank 32 1/2" 42"
14” Quadra-Hull Tank 22 1/2" 52"
Dimension X is the exposed length the Aqua-Sensor cord (cord length
from the Aqua-Sensor plug to the circuit board connector). You can
then verify the Aqua-Sensor probe is inserted to the proper depth by
confirming that Dimension X is at the correct length.
Table 1. HE Twin cable lengths.
NOTE Only one Aqua-Sensor probe is used for HE Twin
applications.
2. Loosen the small Aqua-Sensor Plug; a needle-nose pliers
works best. See Figure 3.
3. Moisten the cable sheath and slide the cable grip up or
down to the proper cable length.
4. Tighten the small Aqua-Sensor plug so that the fitting
cannot slide along the cable.
NOTE There must be no kinks or bends in the cable.
5. Insert the probe and cable through the Aqua-Sensor port.
6. Tighten the Aqua-Sensor plug into the Aqua-Sensor port.
NOTE Follow Aqua-Sensor programming procedures—see page 44.
Figure 2. HE Softener tank.
Small
Aqua-Sensor
®
Plug
Figure 3. Aqua-Sensor plug.