Specifications
57
California
Certificates
State of California
Department of Public Health
Water Treatment Device
Certificate Number
Date Issued: July 16, 2010
Trademark/Model Designation
Replacement Elements
Tank Capacity
196210 -
Culligan International Company Aqua-Cleer Advanced
Drinking Water System with RO30, TD and AS3
RO-30 01020268 - RO Membrane
TD - 01020274 - Post Filter
AS3 - P1020272 - Post Filter
2 gallons
Manufacturer: Culligan International Company
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Cysts (protozoan)
Turbidity
Arsenic
1
(pentavalent) 50 ppb
Arsenic
1
(trivalent) 50 ppb
Barium
Cadmium
Chromium (hexavalent)
Chromium (trivalent)
Copper
Fluoride
Lead
Nitrate/Nitrite
2
Radium 226/228
Selenium
MTBE
VOCs
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Organic Contaminants
0.035 gpmRated Service Flow:
Alachlor
Bromodichloromethane
1
Carbon Tetrachloride
2,4-D
o-Dichlorobenzene
1,2-Dichloroethane
cis-1,2-Dichloroethylene
Dinoseb
Ethylbenzene
Hexachlorocyclopentadiene
Methoxychlor
Styrene
1,1,2,2-Tetrachloroethane
1,1,1-Trichloroethane
m-Xylene
1
Trihalomethanes
Benzene
Carbofuran
Chloroform
1
Dibromodichloromethane
1
1,1-Dichloroethane
1,1-Dichloroethylene
cis-1,3-Dichloropropylene
Endrin
Heptachlor Epoxide
Lindane
Simazine
Tetrachloroethylene
1,2,4-Trichlorobenzene
Trichloroethylene
p-Xylene
Atrazine
Bromoform
1
Chlorobenzene
DBCP
p-Dichlorobenzene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
EDB
Heptachlor
Hexachlorobutadiene
Pentachlorophenol
2,4,5-TP (Silvex)
Toluene
1,1,2-Trichloroethane
o-Xylene
1
Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at
the reverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1
minute chlorine contact time before the RO system.
Do not use where water is microbiologically unsafe or with water of unknown quality, except that
systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
1000 galRated Service Capacity:
2
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L
nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a
pressure of 280 kPa (40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the