Specifications

42
Performance
Data Sheet
(con’t)
Output (Total Dissolved Solids (TDS) Reduction and Output Production)
1
RO30
Tank Size 2 gallon 3 gallon 9 gallon
Product System Daily Prod. Rate To Pressurized Storage
Tank
11.09 gpd 11.09 gpd 11.09 gpd
Prod. Rate without Storage Tank To Atmosphere 36 gpd 36 gpd 36 gpd
Efciency Rating
2
16.86% 16.86% 16.86%
Recovery Rating
3
28.84% 28.84% 28.84%
Inuent Challenge Concentration (Mg/L) 770 770 770
Max. Permissible Product Water Concentration (Mg/L) 187 187 187
Minimum Percent Removal 93.1% 93.1% 93.1%
Average Percent Removal 95.4% 95.4% 95.4%
1 This is a factory specication for membrane production. Actual production rate and TDS rejection will depend on temperature, water pressure, TDS
level, membrane variation and usage pattern.
2 Efciency rating means the percentage of the inuent water to the system that is available to the user are reverse osmosis treated water under
operating conditions that approximate daily usage.
3 Recovery rating means the percentage of the inuent water to the membrane portion of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Output (Total Dissolved Solids (TDS) Reduction and Output Production)
1
RO50*
Tank Size 2 gallon 3 gallon 9 gallon
Product System Daily Prod. Rate To Pressurized Storage
Tank
16.16 gpd 16.16 gpd 16.16 gpd
Prod. Rate without Storage Tank To Atmosphere 50 gpd 50 gpd 50 gpd
Efciency Rating
2
18.98% 18.98% 18.98%
Recovery Rating
3
31.37% 31.37% 31.37%
Inuent Challenge Concentration (Mg/L) 770 770 770
Max. Permissible Product Water Concentration (Mg/L) 187 187 187
Minimum Percent Removal 86.6% 86.6% 86.6%
Average Percent Removal 92.3% 92.3% 92.3%
1 This is a factory specication for membrane production. Actual production rate and TDS rejection will depend on temperature, water pressure, TDS
level, membrane variation and usage pattern.
2 Efciency rating means the percentage of the inuent water to the system that is available to the user are reverse osmosis treated water under
operating conditions that approximate daily usage.
3 Recovery rating means the percentage of the inuent water to the membrane portion of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage tank or when the storage tank is bypassed.
*RO50 not for sale in California.
Testing Conditions (Complete System)
Temperature: 77º F + 2º F pH: 7.5 + 0.5
Pressure: 50 psi Turbidity: <1 NTU
This system has been tested and shown to operate at its calculated recovery rating under
standard laboratory conditions.
This reverse osmosis system contains a replaceable component critical to the efficiency
of the system. Replacement of the reverse osmosis component should be with one of
identical specifications, as defined by the manufacturer, to assure the same efficiency and
contaminant reduction performance.