Specifications

31
Performance
Data Sheet
(con’t)
RO50* with TD
These systems have been tested and certified by NSF International according to NSF/ANSI
42, 53, and 58 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 42, 53, and 58.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L
nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite
reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater.
Substance Reduction
1
Substance Inuent Challenge
Concentration
mg/L
Maximum
Permissible
Product water
Concentration
mg/L
Reduction
Require-
ments
Minimum
Reduction
Average
Reduction
Arsenic (pen-
tavalent)2
0.30 +/- 10% 0.01
99.3%
Barium 10.0 +/- 10% 2 98.5%
Cadmium 0.03 +/- 10% 0.005 98.1%
Hexavalent
Chromium
0.30 +/- 10% 0.05
97.7%
Trivalent Chro-
mium
0.30 +/- 10% 0.05
99.0%
Copper 3.00 +/- 10% 1.3 98.7%
Fluoride 8.0 +/- 10% 1.5 95.5%
Lead 0.15 +/- 10% 0.010 98.1%
Nitrate/Nitrite
(both as N)
30 +/- 10%
65.9% 68.9%
Nitrate5 27.0 +/- 10% 10.0 66.2% 68.5%
Nitrite 3.0 +/- 10% 1.0 65.5% 69.8%
Radium
226/2283
25pCi/L +/- 10% 5pCi/L
80.0%
Selenium 0.10 +/- 10% 0.05 94.0%
Cyst4 >50,000/mL 99.95% 99.99% 99.99%
Turbidity 11 +/- 1 NTU 0.5 NTU 99.3%
1 While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressure, temperatures and
other substances, which may be found in your water.
2 This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations
of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water sup-
plies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent
arsenic. Treatment with chloramines (combined chlorine) is not sufcient to ensure complete conversion of trivalent arsenic to pentavalent arsenic.
Please see the Arsenic Facts Sheet for further information.
3 Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.
4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.
5 Units are not certied on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.
*RO50 not for sale in California.