Specifications
26
AS3
The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances
listed below. The concentration of the indicated substances in the water entering the
system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 53. Conforms to NSF/ANSI Standard 53 for
arsenic (trivalent and pentavalent) reduction. See Arsenic Fact section for an explanation
of reduction performance.
Substance Inuent
Challenge
Concentration
mg/L
Maximum
Permissible
Product
water Con-
centration
mg/L
Reduction
Require-
ments
Minimum
Reduction
Average
Reduction
Standard 53
Trivalent Arsenic pH 6.5 0.050 + 10% 0.010 94.9%
Trivalent Arsenic pH 8.5 0.050 + 10% 0.010 98.0%
Pentavalent Arsenic 0.050 + 10% 0.010 97.4%
Flow Rate = 0.035 gpm (0.13 Lpm)
Capacity = 1000 gallons (3786 L)
1000 gallon capacity is only for use with PID
Testing was performed under standard laboratory conditions, actual performance may vary
Performance
Data Sheet
(con’t)
RO30 with AS3, TD (continued)
Fluoride 8.0 +/- 10% 1.5 95.6%
Lead 0.15 +/- 10% 0.010 98.7%
Nitrate/Nitrite (both as
N)
30 +/- 10% 83.1% 86.8%
Nitrate
5
27.0 +/- 10% 10.0 83.4% 87.0%
Nitrite 3.0 +/- 10% 1.0 79.5% 84.8%
Radium 226/2283 25pCi/L +/- 10% 5pCi/L 80.0%
Selenium 0.10 +/- 10% 0.05 96.0%
Cyst
4
>50,000/mL 99.95% 99.99% 99.99%
Turbidity 11 +/- 1 NTU 0.5 NTU 99.00%
1 While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressure, temperatures and
other substances, which may be found in your water.
2 This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations
of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pen-
tavalent arsenic. Treatment with chloramines (combined chlorine) is not sufcient to ensure complete conversion of trivalent arsenic to pentavalent
arsenic. Please see the Arsenic Facts Sheet for further information.
3 Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.
4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.
5 Units are not certied on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.