Datasheet

cui.com
CUI Inc SERIES: VHB200W DESCRIPTION: DC-DC CONVERTER date 04/01/2013 page 2 of 4
INPUT
parameter conditions/description min typ max units
operating input voltage
10
18
24
48
36
75
Vdc
Vdc
under voltage lockout
power up
power down
24 V input
48 V input
24 V input
48 V input
9.5
17
8.5
16
Vdc
Vdc
Vdc
Vdc
positive logic remote on/off
1
lter PI type
Notes: 1. logic compatibility, open collector ref to -input
Module ON, >3.5 Vdc or open circuit
Module OFF, <1.8 Vdc
OUTPUT
parameter conditions/description min typ max units
line regulation measured from high line to low line ±0.2 %
load regulation measured from full load to zero load ±0.2 %
voltage accuracy ±1.5 %
transient response 25% step load change 500 µs
adjustability
2
±10 %
switching frequency 100% load, input voltage range 250 kHz
temperature coefcient ±0.03 %/°C
Notes: 2. trim-up: connect a resistor between the trim pin and +Sense
trim-down: connect a resistor between the trim pin and -Sense
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection %Vo 115 140 %
short circuit protection continuous
current limit % nominal output current 110 150 %
thermal shutdown case temp. 110 °C
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output
input to case
output to case
1,500
1,500
1,500
Vdc
Vdc
Vdc
isolation resistance 10 MΩ
isolation capacitance 1,000 pF
safety approvals UL60950-1
RoHS compliant yes
For more information, please visit the product page.