Datasheet

cui.com
CUI Inc SERIES: PYB30-U DESCRIPTION: DC-DC CONVERTER date 08/18/2014 page 3 of 7
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage for 1 minute at 1 mA max. 1,500 Vdc
isolation resistance at 500 Vdc 1,000 MΩ
conducted emissions CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b)
radiated emissions CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b)
ESD IEC/EN61000-4-2, class B, contact ± 4kV
radiated immunity IEC/EN61000-4-3, class A, 10V/m
EFT/burst IEC/EN61000-4-4, class B, ± 2kV (external circuit required, see Figure 1-a)
surge IEC/EN61000-4-5, class B, ± 2kV (external circuit required, see Figure 1-a)
conducted immunity IEC/EN61000-4-6, class A, 3 Vr.m.s
voltage dips & interruptions IEC/EN61000-4-29, class B, 0%-70%
MTBF as per MIL-HDBK-217F @ 25°C 1,000,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature see derating curve -40 85 °C
storage temperature -55 125 °C
storage humidity non-condensing 5 95 %
case temperature at full load, Ta=71°C 105 °C
MECHANICAL
parameter conditions/description min typ max units
dimensions
U-Frame: 67.5 x 54.99 x 19.05
U-Frame with heatsink: 67.5 x 54.99 x 22.90
mm
mm
case material aluminum alloy
weight
U-Frame
U-Frame with heatsink
58
78
g
g
PROTECTIONS
parameter conditions/description min typ max units
short circuit protection hiccup, continuous, automatic recovery
over current protection 150 %
over voltage protection
3.3 Vdc output models
5 Vdc output models
12 Vdc output models
15 Vdc output models
3.9
6.2
15
18
Vdc
Vdc
Vdc
Vdc
For more information, please visit the product page.