date 11/07/2014 │ page 3 of 30CUI Inc │ SERIES: NQB-N │ DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS
General Information
Reliability
The failure rate (λ) and mean time between failures 
(MTBF= 1/ λ) is calculated at max output power and 
an operating ambient temperature (T
A
) of +40°C. CUI 
Power Modules uses Telcordia SR-332 Issue 2 Method 1 to 
calculate the mean steady-state failure rate and standard 
deviation (σ). 
Telcordia SR-332 Issue 2 also provides techniques to 
estimate the upper condence levels of failure rates based 
on the mean and standard deviation.
Mean steady-state failure rate, λ  Std. deviation, σ 
h/seruliaFn9.06h/seruliaFn124
MTBF (mean value) for the NQB series = 2.9 Mh.
MTBF at 90% condence level = 2.4 Mh
Compatibility with RoHS requirements
The products are compatible with the relevant clauses 
and requirements of the RoHS directive 2011/65/EU and 
have a maximum concentration value of 0.1% by weight 
in homogeneous materials for lead, mercury, hexavalent 
chromium, PBB and PBDE and of 0.01% by weight in 
homogeneous materials for cadmium.
Exemptions in the RoHS directive utilized in CUI 
Power Modules products are found in the Statement of 
Compliance document.
Safety Specification
Reliability
CUI Power Modules DC/DC converters and DC/DC 
regulators are designed in accordance with the safety 
standards IEC 60950 1, EN 60950 1 and UL 60950 1 
Safety of Information Technology Equipment.
IEC/EN/UL 60950 1 contains requirements to prevent 
injury or damage due to the following hazards:
•  Electrical shock
•  Energy hazards
• Fire
•  Mechanical and heat hazards
•  Radiation hazards
•  Chemical hazards
On-board DC/DC converters and DC/DC regulators are 
dened as component power supplies. As components 
they cannot fully comply with the provisions of any 
safety requirements without “conditions of acceptability”. 
Clearance between conductors and between conductive 
parts of the component power supply and conductors on 
the board in the nal product must meet the applicable 
safety requirements. Certain conditions of acceptability 
apply for component power supplies with limited stand-off 
(see Mechanical Information for further information). It is 
the responsibility of the installer to ensure that the nal 
product housing these components complies with
the requirements of all applicable safety standards and 
regulations for the nal product. 
Component power supplies for general use should comply 
with the requirements in IEC/EN/UL 60950 1 Safety 
of Information Technology Equipment. Product related 
standards, e.g. IEEE 802.3af Power over Ethernet, and 
ETS 300132 2 Power interface at the input to telecom 
equipment, operated by direct current (dc) are based on 
IEC/EN/UL 60950 1 with regards to safety.
CUI Power Modules DC/DC converters and DC/DC 
regulators are UL 60950 1 recognized and certied in 
accordance with EN 60950 1. The ammability rating for 
all construction parts of the products meet requirements 
for V 0 class material according to IEC 60695 11 10, Fire 
hazard testing, test ames – 50 W horizontal and vertical 
ame test methods.
Isolated DC/DC converters
Galvanic isolation between input and output is veried 
in an electric strength test and the isolation voltage 
(V
iso
) meets the voltage strength requirement for basic 
insulation according to IEC/EN/UL 60950-1. 
It is recommended to use a slow blow fuse at the input 
of each DC/DC converter. If an input lter is used in the 
circuit the fuse should be placed in front of the input lter. 
In the rare event of a component problem that imposes a 
short circuit on the input source, this fuse will provide the 
following functions:
•  Isolate the fault from the input power source so as 
  not to affect the operation of other parts of   
  the system
•  Protect the distribution wiring from excessive   
  current and power loss thus preventing hazardous 
 overheating
The DC/DC converter output is considered as safety extra 
low voltage (SELV) if one of the following conditions is 
met:
•  The input source has double or reinforced   
  insulation from the AC mains according to IEC/EN/ 
  UL 60950-1
•  The input source has basic or supplementary   
  insulation from the AC mains and the input   
  of the DC/DC converter is maximum 60   
  Vdc and connected to protective earth according to 
  IEC/EN/UL 60950-1
•  The input source has basic or supplementary   
  insulation from the AC mains and the DC/DC   
  converter output is connected to protective earth 
  according to IEC/EN/UL 60950-1
Non - isolated DC/DC regulators
The DC/DC regulator output is SELV if the input source 
meets the requirements for SELV circuits according to IEC/
EN/UL 60950-1. 
For more information, please visit the product page.