Datasheet

cui.com
date 11/07/2014 page 8 of 36CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS
Typical Characteristics
12.0 V, 35 A / 420 W
nwod-tuhS pu-tratS
Start-up enabled by connecting V
I
at:
T
P1
, T
P3
= +25°C, V
I
= 53 V,
I
O
= 35 A resistive load.
Top trace: output voltage (5 V/div.).
Bottom trace: input voltage (50 V/div.).
Time scale: (10 ms/div.).
Shut-down enabled by disconnecting V
I
at:
T
P1
, T
P3
= +25°C, V
I
= 53 V,
I
O
=35 A resistive load.
Top trace: output voltage (5 V/div.).
Bottom trace: input voltage (50 V/div.).
Time scale: (2 ms/div.).
esnopseR tneisnarT daoL tuptuO esioN & elppiR tuptuO
Output voltage ripple at:
T
P1
, T
P3
= +25°C, V
I
= 53 V,
I
O
= 35 A resistive load.
Trace: output voltage (50 mV/div.).
Time scale: (2 µs/div.).
Output voltage response to load current
step-change (8.75-26.25-8.75 A) at:
T
P1
, T
P3
=+25°C, V
I
= 53 V, C
O
= 3.5 mF.
Top trace: output voltage (0.5 V/div.).
Bottom trace: output current (20 A/div.).
Time scale: (0.5 ms/div.).
esnopseR tneisnarT egatloV tupnI
Output voltage response to input voltage
transient at:
T
P1
, T
P3
= +25°C, V
I
= 36-75 V,
I
O
= 17 A resistive load, C
O
= 3.5 mF
Top trace: output voltage (2 V/div.).
Bottom trace: input voltage (20 V/div.).
Time scale: (0.5 ms/div.).