5. ENVIRONMENTAL AND AGENCY REQUIREMENTS
The DCU2 is designed to operate under the following conditions:
Electro-magnetic compatibility (EMC):
Immunity: EN61000-6-2 (2001) CE class B, ISO7637-2
Emissions: EN 61000-6-3 (2001) CE class B;
e-marking; ISO7673-2; Electrical/electronic devices.
This standard is applicable for equipment mounted on
vehicles for the European market.
Motor Vehicle EMC Directive 2004/104/EC; Annex I,
Section 3.2.9.
Operating temperature:
-20 to +60 °C (–4 °F to 140 °F)
Storage temperature:
-30 to +80 °C (–22 °F to 176 °F).
Humidity: 15 to 95 percent Relative Humidity (RH), non-
condensing.
Vibration: MIL-STD 810 (latest revision), Method 514.3, category
8 modified.
Shock: MIL-STD 810 (latest revision), Method 516-3,
procedure I, 20 g, 11ms.
Moisture and Solids Resistance: EN 60529 (1992)
IP54
Flammability: UL 94 V-0.
5.1 ELECTRIC SAFETY
The DCU2 is designed to meet UL and Œ requirements as well as EN60950. The DCU2 will be Œ
certified and marked. UL testing will only be performed as required by customer contract.