3. Starting Sensor Operation
AH100 Asset Tracker has 4 modes of operation:
1. All Features (Motion Detection + Temp/Humidity Measurement)
2. Motion Only
3. Temp+Humidity Only
4. Radio Test
The check-in interval should be entered prior to pressing on the start buttons. Any configuration to the
operation such as the motion sensitivity settings or automatic motion muting trigger count need to be
updated before starting the operation.
The standard mode of operation is the All Features operation, in which the continuous motion detection
and periodic measurement of temperature and humidity are both enabled. If either motion detection or
temp+humidity measurement is not required, Temp+Humidity Only mode or Motion Only mode can be
used, respectively. Temp+Humidity Only mode has the lowest power consumption, and can extend the
battery life.
In Radio Test the unit will periodically send a beacon radio packet indefinitely. This mode can be used for
wireless testing and sensor positioning.
Important Note: Radio Test mode will continue indefinitely until “Stop Operation” button is pressed.
To start All Features / Motion Only / Temp+Humidity Only sensing operation:
1. Place AH100 sensor on the Optical Programmer, face down
2. Go to “Action” tab in the GUI
3. As needed, change the desired check-in interval (Default is 600 seconds, or 10 minutes)
4. Press the desired start button
Starting AH100 Sensing Operation