Operation
1. Optical Interface
AH100 uses an optical programming interface to receive commands and change configurations. Each time
a button is pressed on the GUI, an optical packet is transmitted, which is easily identified by the flashing
of bright white LED. This process takes 3-5 seconds.
Important Note: Optical communication must be performed indoors in a room without direct sunlight to
prevent background illumination and within the temperature range of 21-27
o
C. If a unit had been exposed
to outdoor temperature, please allow at least 10 minutes for the sensor to acclimate to indoor
temperature.
To use the optical programming interface:
1. Confirm blue indicator light flashing on the optical programmer.
2. Place AH100 sensor on the indented section of the optical programmer.
3. The AH100 sensor needs to be placed with the top side facing down, so that the light sensor faces
the programmer (see picture below).
4. Click on appropriate button on the GUI as explained below.
5. Wait until the white LED stops blinking (optical packet transmitted) before clicking any other
buttons.
AH100’s optical sensor should face the optical programmer’s LED