Full Product Manual
17
SERVICE AND MAINTENANCE
LCD Screen Messages
Message Description
Brake Switch Fault: The deck and
drive shut off. Power off and restart
tractor. If problem persists contact
qualified service personnel.
Accelerator Pedal Sensor Fault:
The deck and drive shut off. Power off
and restart tractor. If problem persists
contact qualified service personnel.
Seat Switch Fault: The deck and
drive shut off. Power off tractor,
sit in seat and restart tractor. If
problem persists contact qualified
service personnel.
Cutting Deck Overload: The
deck and drive shut off. Power off
the tractor, clean under the deck
as instructed in the Post-Operation
Tractor Care section and restart the
tractor. Raise the deck and/or cut at
a slower pace. If problem persists
contact qualified service personnel.
Drive Motor Over Current Fault:
The deck and drive shut off. Power
off, let the tractor cool and restart
tractor. If problem persists contact
qualified service personnel.
Drive Motor Control Fault: The
deck and drive shut off. Power off and
restart tractor. If problem persists
contact qualified service personnel.
Troubleshooting
Problem Cause Remedy
Excessive Vibration 1. Blade loose or unbalanced
2. Cutting blade damaged, unbalanced or bent.
1. Tighten cutting blade and deck spindle
2. Replace the blade
Uneven Cut 1. Deck not properly leveled
2. Cutting blade dull or damaged
3. Uneven tire pressure
1. Perform front-to-rear deck adjustment
2. Sharpen or replace cutting blade
3. Check and correct tire pressure in all four tires
Tractor will not mulch grass 1. Wet grass
2. Excessively high grass
3. Dull blade
1. Do not mulch when grass is wet
2. Mow once at a high cutting height, then mow again at
desired height or make a narrower cutting swath
3. Sharpen or replace blade
Tractor stopped or will not start 1. Electrical system fault 1. Shut off and restart tractor. If problem persists, contact an
authorized service dealer
The blades do not rotate /blades stopped 1. Overload
2. Low battery
1. Allow deck motor(s) to cool/raise deck height
2. Return home, plug into charger
The blade(s) stopped when traveling in
reverse
1. Blade(s) stopped 1. Restart blade(s) (PTO). Make sure Reverse Caution Mode is
activated.
Reduced Speed 1. Low battery
2. Overload
1. Charge battery as instructed in the battery charger manual
2. Raise deck
Message Description
Self Test Fault: The deck and
drive shut off. Power off and restart
tractor. If problem persists contact
qualified service personnel.
Electrical Faults: The deck and
drive shut off. Power off and restart
tractor. If problem persists contact
qualified service personnel.
Battery Temperature Low:
Move the tractor to a warm
location and allow the battery to
warm. If problem persists contact
qualified service personnel.
High Temperature Faults:
Power off, let the tractor cool
and restart tractor. If problem
persists contact qualified service
personnel.
Charge Port Door is Open: The
tractor will come to a stop and shut
off. Close the charge port door and
restart tractor. If problem persists
contact qualified service personnel.
Low Battery Warning: The
battery is low and should be
charged as soon as possible.