Manual

27 G730
INPUT SHAFT
RefertoFigure19
Disassembly
1. Requires removal of all items beginning on
page 22.
2. Remove the retaining ring (57).
3. Remove the lip seal (56) and discard.
4. Remove the washer (55) and the pump shaft
assembly (52–53).
NOTE: Toassistintheremovalofthepump
shaft, lightly tap (using a neoprene
head hammer) the shaft from the
charge pump side of housing. Care
should be taken not to damage the
shaftorgerotorrunningsurface.
Removethebearingfrompumpshaft
onlyifwornordamaged.
5. Remove the wire ring retainer (54) and the
bearing (53) from the pump shaft (52).
Inspection
1. Inspect the bearing and input shaft for
wear or damage. Inspect the splines on
the shaft for possible damage.
Replace if necessary.
Figure 19, Input Shaft
Assembly
1. Reassemble all parts in the reverse order
of disassembly.
57
56
55
54
53
52