SDS
Material Safety Data Sheet
Report No.:STRD1405012S Page 5 of 10
Shenzhen SEM.Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd
Road, Bao'an District, Shenzhen, P.R.C. (518101)
Methods and materials for cleaning up Absorb spilled material with an inert absorbent
(dry sand or earth). Scoop contaminated
absorbent into an acceptable waste container.
Collect all contaminated absorbent and dispose
of according to directions in Section 13. Scrub
the area with detergent and water; collect all
contaminated wash water for proper disposal.
Section 7 – Handling and Storage
Handling Do not dismantle, open or shred secondary
Lithium-ion Battery;
Don’t handling Lithium-ion Battery with
metalwork. Do not open, dissemble, crush or
burn battery. Ensure good ventilation/
exhaustion at the workplace.
Prevent formation of dust.
Information about protection against explosions
and fires: Keep ignition sources away- Do not
smoke.
Storage If the Lithium-ion Battery is subject to storage for
such a long term as more than 3 months, it is
recommended to recharge the Lithium-ion
Battery periodically.
3 months: -10℃~+40℃, 45 to 85%RH
And recommended at 0℃~+35℃ for long period
storage.
The capacity recovery rate in the delivery state
(50% capacity of fully charged) after storage is
assumed to be 80% or more.
The
voltage
for
a
long
time
storage
shall
be
14.04V~15.04V range.
Do not storage Lithium-ion Battery haphazardly
in a box or drawer where they may short-circuit
each other or be short-circuited by other metal
objects.
Keep out of reach of children.
Do not expose Lithium-ion Battery to heat or fire.
Avoid storage in direct sunlight.
Do not store together with oxidizing and acidic
materials.
Section 8 – Exposure Controls and Personal Protection
Engineering Controls Use local exhaust ventilation or other
engineering controls to control sources of dust,