Service manual

CHAPTER 6 8454
6-62
D569-W02 May-2003
c. To Assemble the Control
1. Insert the dust seal into the flange section of the
housing.
b .To Disassembling the Relief Valve
1. Loosen retainer screw (1) on plug (29) area of hous-
ing (20) and take out retainer pin (2) and ball (3).
2. Loosen relief adjusting plug (29) with the flange
face of housing (20) upward and remove O-ring (28).
3. Remove damper collar (8) and spring (5) out.
4. Take poppet (4) out of housing (20) using a pin set.
(1) Screw (26) Spring
(2) Retainer Pin (27) Damper Collar
(3) Ball (28) O-Ring
(25) Poppet (29) Adjusting Plug
CAUTION
CAUTION
Previously measure the depth from the
flange faced and of the housing to the
relief adjusting plug (7) with binary cali-
pers to easily perform adjustment of
the pressure when reassembling.
Install the flat surface of the dust room
downward.
569W687A
569W688A
(32) Dust Seal
2. With the flange face of the housing downward, in-
sert O-ring (30) onto the assembling groove to fix
with one bearingless (18), thrust needle bearing
(19) and the other bearingless (18).
569W689A
(18) Bearingless (30) O-ring
(19) Needle Bearing
www.mymowerparts.com
K&T Saw Shop 606-678-9623 or 606-561-4983