User Manual

310-3000 IHT 33
Hydrostatic Transaxle: A multicomponent as sem bly including a gear case and a hydrostatic
trans mis sion.
Hydrostatic Transmission: The combination of a hy drau lic pump and motor in one housing to
form a de vice for the control and transference of power.
Inlet Line: A supply line to the pump.
Integrated Hydrostatic Transaxle (IHT): The com bi na tion of a hydrostatic transmission and
gear case in one housing to form a complete transaxle.
Manifold: A conductor which provides multiple con nec tion ports.
Neutral: Typically described as a condition in which uid ow and system pressure is below that
which is required to turn the output shaft of the motor.
Pressure Decay: A falling pressure.
Priming: The lling of the charge circuit and closed loop of the uid power system during start
up, fre quent ly achieved by pressurizing the uid in the inlet line.
Purging: The act of replacing air with uid in a uid power system by forcing uid into all of the
com po nents and allowing the air a path of es cape.
Rated Flow: The maximum ow that the power sup ply system is capable of maintaining at a
spe ci c op er at ing pressure.
Scoring: Scratches in the direction of motion of me chan i cal parts caused by abrasive con tam i-
nants.
Swash Plate: A mechanical device used to con trol the displacement of the pump pistons in a
uid power sys tem.
System Charge Check Valve: A valve con trol ling the replenishing ow of uid from a charge
circuit to the closed loop in a uid power system.
System Pressure: The pressure which over comes the total resistance in a system, in
clud ing
all losses.
Valve: A device which controls uid ow di rec tion, pressure, or ow rate.
Variable Displacement Pump: A pump in which the displacement per cycle can be varied.
Volumetric Displacement: The volume for one rev o lu tion.